Features
- 30 standard frequencies between 1.544 MHz and 49.152 MHz
- Four industry-standard packages:
2.7 x 2.4 mm (4-pin, compatible with 2.5 x 2.0 mm footprint)
3.2 x 2.5 mm (4-pin), 5.0 x 3.2 mm (6-pin), 7.0 x 5.0 mm (6-pin) - Frequency stability as tight as ±25 x 10-6
- Widest pull range options from ±25 to ±200 x 10-6
Applications
- Telecom clock synchronization, instrumentation
- Low bandwidth analog PLL, jitter cleaner, clock recovery, audio
- Video, 3G/HD-SDI, FPGA, broadband and networking
Standard Specification[1,2,3]
Item | Symbol | Min. | Typ. | Max. | Unit | Condition |
---|---|---|---|---|---|---|
Output Frequency Range | f | 1.544 | - | 49.152 | MHz | Refer to datasheet for exact list of supported frequencies |
Supply Voltage | Vdd | +1.71 | +1.8 | +1.89 | V | Additional supply voltages between +2.5V and +3.3V can be supported. |
+2.25 | +2.5 | +2.75 | ||||
+2.52 | +2.8 | +3.08 | ||||
+2.97 | +3.3 | +3.63 | ||||
+2.25 | - | +3.63 | ||||
Operating Temperature Range | T_use | -20 | - | +70 | ℃ | Extended Commercial |
-40 | - | +85 | Industrial | |||
Frequency Stability | F_stab | -25 | - | +25 | ×10-6 | Inclusive of Initial tolerance[4] at +25°C, and variation over temperature, rated supply voltage and load. |
-50 | - | +50 | ||||
10-year Aging | F_aging10 | -5.0 | - | +5.0 | ×10-6 | 10 years, TA = +25°C |
Current Consumption | Idd | - | +31 | +33 | mA | No load condition, f = 20 MHz, Vdd = +2.5V, +2.8V or +3.3V |
- | +29 | +31 | No load condition, f = 20 MHz, Vdd = +1.8V | |||
Standby Current | I_std | - | - | +70 | μA | Vdd = +2.5V, +2.8V or +3.3V, ST = GND, Output is weakly pulled down |
- | - | +10 | Vdd = +1.8V, ST = GND, Output is weakly pulled down | |||
Duty Cycle | DC | 45 | - | 55 | % | All Vdds |
Output Low Voltage | VOL | - | - | Vdd x 0.1 | V | IOL = +7.0 mA (Vdd = +3.0V or +3.3V) IOL = +4.0 mA (Vdd = +2.8V or +2.5V) IOL = +2.0 mA (Vdd = +1.8V) |
Output High Voltage | VOH | Vdd x 0.9 | - | - | V | IOH = -7.0 mA (Vdd = +3.0V or +3.3V) IOH = -4.0 mA (Vdd = +2.8V or +2.5V) IOH = -2.0 mA (Vdd = +1.8V) |
Rise/Fall Time | Tr,Tf | - | 1.5 | 2.0 | ns | Vdd = +1.8V, +2.5v, +2.8V or +3.3V, 10% - 90% Vdd level |
Pull Range[5,6] | PR | ±25, ±50, ±100, ±150, ±200 | ×10-6 | See the Absolute Pull Range and APR table of datasheet | ||
Upper Control Voltage | VC_U | +1.7 | - | - | V | Vdd = +1.8V, Voltage at which maximum deviation is guaranteed. |
+2.4 | - | - | Vdd = +2.5V, Voltage at which maximum deviation is guaranteed. | |||
+2.7 | - | - | Vdd = +2.8V, Voltage at which maximum deviation is guaranteed. | |||
+3.2 | - | - | Vdd = +3.3V, Voltage at which maximum deviation is guaranteed. | |||
Lower Control Voltage | VC_L | - | - | +0.1 | V | Voltage at which minimum deviation is guaranteed. |
Control Voltage Input Impedance | Z_in | - | 1.6 | 2.5 | kΩ | For the OE/ST pin for 6-pin devices |
Control Voltage Input Capacitance | C_in | - | 1.8 | 3.0 | pF | For the OE/ST pin for 6-pin devices |
Linearity | Lin | - | 0.1 | 1.0 | % | |
Frequency Change Polarity | - | Positive slope | - | |||
Startup Time | T_start | - | - | 10 | ms | |
OE Enable/Disable Time | T_oe | - | - | 180 | ns | f = 40MHz, all Vdds, For other freq., T_oe = 100 ns + 3 clock periods |
Resume Time | T_resume | - | 7.0 | 10 | ms | |
RMS Period Jitter | T_jitt | - | 1.5 | 2.0 | ps | f = 20MHz, Vdd = +2.5V, +2.8V or +3.3V |
- | 2.0 | 3.0 | f = 20MHz, Vdd = +1.8V | |||
RMS Phase Jitter (random) | T_phj | - | 0.5 | 1.0 | ps | f = 20MHz, Integration bandwidth = 12kHz to 20MHz, All Vdds |
Packing Unit | 1000pcs./reel(φ180)or 3000pcs./reel(φ180 : 2724, 3225 package) |
[1]. All electrical specifications in the above table are specified with 15 pF output load and for all Vdd(s) unless otherwise stated.
[2]. The typical value of any parameter in the Electrical Characteristics table is specified for the nominal value of the highest voltage option for that parameter and at +25 °C temperature.
[3]. All max and min specifications are guaranteed across rated voltage variations and operating temperature ranges, unless specified otherwise
[4]. Initial tolerance is measured at Vin = Vdd/2
[5]. Absolute Pull Range (APR) is defined as the guaranteed pull range over temperature and voltage.
[6]. APR = pull range (PR) - frequency stability (F_stab) - Aging (F_aging)
Consult our sales representative for other specifications.